    Product overview

    LKM1 series moulded case circuit breaker(herein after called circuit breaker) adopts international advanced design and manufactural technology, it can be divided into L-type (standard type), M-type (higher type)according to the rated ultimate short circuit breaking capacity (Icu). With the features of small and compact, high breaking capacity, short arcing-over distance, anti-vibration, the circuit breaker is used popularly on land and marine products, which are applied for the power distribution network of AC 50Hz,rated insulation voltage 800V (LKM1-63 to 500V), rated working voltage 690V(LKM1-63 to 400V) and below, rated current up to 1600A. It can be used to distribute electric power and protect power equipment against overload, short circuit, undervoltage etc, It also takes protective effect when motors infrequently start and protects against overload, short circuit and lacking voltage. In the series, frame ranging from 63-630A three-pole product also comes with a transparent cover, it is convenient for customers to observe the product operation.

    The circuit breaker can be installed vertically, or horizontally.Standard: IEC60947-2.


    Product selection

    A


    1.Blank for power distribution,2 for motor protection

    2.Blank for direct operation with handle, Z for operation with rotary handle, P for

    motor-driven operation.

    3.There are 2 types of N-pole for 4P breaker:

    A:Without current release components, N-Pole is always at making status(not

    breakers);

    B:Without current release components, N-Pole is made with the other three poles.


    Curve

    B


    Operating conditions

    1.Temperature: -5℃~+40℃; the average value within 24h shall not exceed +35℃. For the circuit breaker with thermo-magnetic

    release, +40℃ is set to be the standard temperature for ratings. For temperature not between -5℃~+40℃, please contact us for Temperature compensation correction;

    2.Altitude: not exceed 2000m (Please contact with us for reduction coefficient if altitude at the mounted site exceed 2000m)

    3.Pollution grade: Grade 3;

    4.Air conditions:

    At mounting site, relative humidity not exceed 50% at the max temperature of +40℃, higher relative humidity is allowable under lower temperature. For example, RH could be 90% at +20℃. Special measures should be taken when dew occurs.


    Technical data

    TypeLKM1-63LKM1-125LKM1-160LKM1-250LKM1-400LKM1-630LKM1-800LKM1-1250LKM1-1600
    PolesP
    33,42,33,432,3,434,34,3, 433
    Rated current InA
    10,16,20, 
    25,32,40,
    50,63
    10, 16,20, 25,
    32,40,50, 63,
    80,100,125
    100,125,
    140,160
    100, 125,
    140 160,
    180, 200,
    225, 250
    225,250,
    315,350,
    400
    400,
    500,
    630
    630,
    700,
    800
    800,
    1000,
    1250
    1600
    Rated insulation voltage UiV
    500800
    Rated impulsewithstand voltage UimpV
    60008000
    Rated operation voltage UeV
    AC400AC400/690
    Breaking capacity class

    LMLMLLMLMLMLMLMLM
    Limit short-circuitbreaking capacity IcukA230V3550355035355050755075-----85
    400V2535255035355050655065757585857585
    690V--810881010201020-30-30-30
    Working short-circuit breaking capacity IcskA230V1850185022225050505050-----50
    400V182218251818253532.53542.5505050503650
    690V--45445510510-15-15-15
    Arcing distancemm50100
    Operating frequencyElectrical life3000300030003000200020002000800500
    mechanical life2000020000200002000010000100001000050002500


    Inner accessories


    Release method
    and accessories code
    Accessories installation
    and down-leads
    Accessories 
    name
    Electromagnetic 
    release
    Complex 
    release
    LKM1-63
    LKM1-125
    LKM1-16
    LKM1-250
    LKM1-400
    LKM1-630
    LKM1-800
    LKM1-1250
    Without parts200300



    Alarm contact208308



    Shunt release210310



    Auxiliary contact220320



    Undervoltage release230330



    Shunt release,Auxiliary contact240340



    Shunt release,under-voltage release250350



    Secondary auxiliary contact260360



    Auxiliary contact,Undervoltage release270370



    Shunt release, Alarm contact218318



    Auxiliary contact, Alarm contact228328



    Undervoltage release, Alarm contact238338



    Shunt release,Auxiliary contact, Alarm contact248348



    Secondary auxiliary contact,Alarm contact268368



    Auxiliary contact,Alarm contact278378




    Overview

    C


    Overall and mounting dimensions(mm)

    D


    TypeOverall size (mm)Installation size (mm)
    WLHW1W2L1H1H2ABΦd
    LKM1-63L781357450-1569228251173.5
    LKM1-63M78135825010315610028251173.5
    LKM1-125L921506860-2008824301294.5
    LKM1-125M92150866012220010524301294.5
    LKM1-160L931517660-2009624301294.5
    LKM1-250L1071658670-21511024351265
    LKM1-250M1071651037014221512724351265
    LKM1-400L1502571079619835716238441947
    LKM1-400M1502571079619835716238441947
    LKM1-630L18227111211624037016542582007
    LKM1-630M18227111211624037016542582007
    LKM1-800M21028011614028038516842702437
    LKM1-1250M
    LKM1-1600M
    210406158140-610193607037511


    Overall and mounting dimensions(mm)

    E



    ModelDimensionsUe(V)Ie(A)Mechanical life(times)Motor power(W)
    ABCDE
    LKM1-63251177410279K1≤0.51400014
    LKM1-100301299011677K1≤0.51400014
    LKM1-250351269011677K1≤0.51400014
    LKM1-40044194130176115K2≤2500035
    LKM1-63058200130176115K2≤2500035
    LKM1-80070243130176115K2≤2500035
    LKM1-125070300130176115K2≤2500035
    LKM1-160070300130176115K2≤2250035

    F